VPSA (Vacuum Pressure Swing Adsorption) oxygen generation system is a derivative of PSA (Pressure Swing Adsorption) technology, tailored for medium and large-scale industrial oxygen production. It operates by utilizing adsorbents (typically zeolite molecular sieves) to separate oxygen from air through alternating cycles of pressure and vacuum. Composed of air compressorsvacuum pumpsadsorption towers, and a control system, VPSA systems are renowned for their high oxygen output, adjustable purity, and wide applicability in industries like metallurgy, chemical engineering, and environmental treatment. PSA oxygen generators, as a broader category encompassing VPSA, rely on the pressure swing adsorption principle to enrich oxygen, serving both industrial and some medical scenarios.

As a medium-to-large industrial equipment, the VPSA oxygen generation system is quite challenging in terms of installation and transportation, so there are a series of requirements: first, to prevent equipment damage; second, to ensure the personal safety of workers during transportation and use is fully guaranteed.

Installation Conditions for VPSA Oxygen Generation Systems

  1. The oxygen generation equipment room should be well-ventilated, with clean and pollution-free incoming air.
  2. Pollutants discharged from the sewage outlet should be exhausted outdoors to avoid on-site pollution.
  3. Equipment installation should refer to the equipment foundation requirements.

Storage and Transportation Conditions for VPSA Oxygen Generation Systems

  1. During transportation, VPSA oxygen generation equipment is strictly prohibited from being inverted, collided, drenched by rain, or subjected to severe vibration.
  2. Packaged oxygen generation equipment should be stored in a well-ventilated indoor space with a relative humidity not exceeding 80%, free of corrosive gases.

Safety Considerations for VPSA Oxygen Generation System Equipment

  1. Except for staff, other people are strictly prohibited from entering the oxygen generation station where the oxygen generation equipment is located at will.
  2. Smoking and open flames are strictly prohibited in the oxygen generation station area. If fire is needed for maintenance, sufficient safety measures must be taken and construction can only be carried out after approval from the safety inspection department.
  3. The oxygen generation station area should be kept tidy. There should be no flammable and explosive items, and other items that block the smooth passage of pedestrians are not allowed to be stacked.
  4. Operators must undergo safety education and learning and practice of operation methods before taking up their posts, and can only work after mastering the operation methods of oxygen generation equipment independently.
  5. Operators must be neatly dressed and operate the equipment strictly in accordance with the provisions of the instruction manual.
  6. At the entrance of the oxygen generation station and in prominent places inside the station, there must be warning signs such as "No Smoking" and "Pay Attention to Safety".
  7. Small dry powder fire extinguishers and other fire-fighting equipment should be equipped in the oxygen generation station.
  8. The pressure gauge used in oxygen generation equipment should be inspected annually, and a seal should be affixed after passing the inspection.
  9. Before the equipment is depressurized, any maintenance work related to pressure is strictly prohibited.
  10. Regularly check the airtightness of equipment pipelines and pipe fittings. If air leakage is found, repair it in time. The equipment can only be started after passing the inspection.
  11. It is recommended that the lighting and ventilation facilities of the oxygen generation station use explosion-proof and safety-type circuits.
  12. Before the first start-up of each equipment, all aspects of the system should be carefully checked to confirm that the equipment has not been damaged during transportation and unloading.
  13. The raw material used by the oxygen generation equipment is air, so the oxygen generation area should maintain good ventilation, and the surrounding air should not be polluted.

In addition to VPSA Oxygen Generators, we also produce PSA Oxygen Generators, storage tanks, heat exchangers and other products. If you are interested in VPSA Oxygen Systems or other products, please feel free to send an email to info@gneeheatex.com. We will be very happy to serve you.


últimas notícias da empresa sobre VPSA Oxygen Generation System: Installation, Storage, Transportation, and Safety Considerations  0

últimas notícias da empresa sobre VPSA Oxygen Generation System: Installation, Storage, Transportation, and Safety Considerations  1

últimas notícias da empresa sobre VPSA Oxygen Generation System: Installation, Storage, Transportation, and Safety Considerations  2

Tempo do bar : 2025-11-06 16:49:55 >> lista da notícia
Contacto
Henan Gnee New Materials Co., Ltd.

Pessoa de Contato: Mrs. Kelly

Telefone: +86 15824687445

Envie sua pergunta diretamente para nós (0 / 3000)